| Sign In | Join Free | My components-electronic.com | 
 | 
Brand Name : kingpo
Model Number : KP-9709
Certification : iso9001 ce
Place of Origin : china
MOQ : 1
Price : To be quoted
Payment Terms : T/T
Supply Ability : 50 set/ month
Delivery Time : 30 working days
Packaging Details : safety carton pack or plywood box
Power : 220V 50/60Hz
standard : IEC 61347-1
PSU1 voltage : 10~500V
PSU1 current : max 3A
IEC61347-1-Figure G.2 – Suitable circuit for producing and applying long-duration pulses
Technical parameters:
1. Test times: 1 ~ 9999 times
 2. Pulse width: 0.01 ~ 9.99 seconds
 Interval: 1 ~ 99 seconds
 3. PSU1 pulse voltage peak adjustable range: 10 ~ 500V
 The maximum output current of PSU1 pulse power supply is 3A, and the load load adjustment rate shall not exceed 2%
 4, R: 100 Ω, C:0.1 uF
 5. The power supply of PSU2 product is additionally configured by the user, and the user inputs it at the terminal of the back panel of the instrument
 6. Output pulse is controlled by high voltage and fast power device, and the starting time is about 1uS
 High backpressure fast reverse bypass diode, recovery time does not exceed 500nS
 7. Pulse observation: test the external oscilloscope by the user
 8. Power supply: AC 220V/50Hz;
 9. Working environment: temperature: 0 ~ 40℃; Relative humidity ≤90% and no condensation
 10. Equipment size: w600mm * d600mm * h500mm, weight about 60kg

Components
 PSU 1 power supply unit, capable of supplying maximum pulse voltage required (maximum of voltage range + X design voltage) with pulse current demanded by invertor at this voltage with 2 % regulation (no load to full load).
 PSU 2 power supply unit adjusted to maximum of input voltage range.
 NOTE 1 Preferably both PSUs should be fitted with current limits to prevent damage in the event of the invertor under test breaking down.
 TH 1 main switching thyristor used to apply voltage pulse to the invertor. Many common thyristors should be suitable for this job. They shall have a turn-on time of about 1 ms and adequate pulse current capability.
 TH 2 thyristor controlling the action of the relay RLC.
 D 1 reverse current by-pass diode for TH 1 . Allows initial oscillatory transients to operate. Shall be fast type (200 ns to 500 ns) with voltage rating equal to twice the maximum pulse voltage.
 D 2 blocking diode for PSU 2 . Prevents output impedance of PSU 2 , loading voltage pulse source (PSU 1 ). Shall be fast type (approximately 1 ms turn off) with voltage rating equal to twice the maximum pulse voltage.
 RLC pulse termination relay with contacts K.
 R and C spark suppression components.
 Suggested values are 1 00 W and 0,1 mF (for 26 V invertors).
 S 1 switch used as ON/OFF or reset control.
 NOTE 2 The delay system for securing the correct duration of the pulse is not represented on the figure. It shall ensure the triggering of thyristor TH 2 500 ms after the action of TH 1 , account being taken of the operating time of the relay.

|   | 
| IEC61347-1-Figure G.2 Circuit For Producing And Applying Long - Duration Pulses Images | 
 Circuit Light Testing Equipment Rectifying Effect Of High Pressure Sodium And
                                                                                    
                        
                        
                        
                                                            Circuit Light Testing Equipment Rectifying Effect Of High Pressure Sodium And
                                                    
                        
                     7006-47C For G5 Lampholders , 7006-60C For G13 Lampholders
                                                                                    
                        
                        
                        
                                                            7006-47C For G5 Lampholders , 7006-60C For G13 Lampholders
                                                    
                        
                     Light Testing Equipment LED Aging Test Device 1000 Hours Test Duration
                                                                                    
                        
                        
                        
                                                            Light Testing Equipment LED Aging Test Device 1000 Hours Test Duration
                                                    
                        
                     IEC 60598-1 Clause 8.15 Arrangement For Impact Test For Handlamps With A Handle
                                                                                    
                        
                        
                        
                                                            IEC 60598-1 Clause 8.15 Arrangement For Impact Test For Handlamps With A Handle
                                                    
                        
                     IEC 61347-1 Annex D Test Chamber Heating Enclosure For Thermally Protected
                                                                                        
                                                        
                        
                        
                        
                                                            IEC 61347-1 Annex D Test Chamber Heating Enclosure For Thermally Protected
                                                    
                        
                     Double-walled cylinder , IEC 60598-1 Annex K Temperature measurement
                                                                                    
                        
                        
                        
                                                            Double-walled cylinder , IEC 60598-1 Annex K Temperature measurement
                                                    
                        
                     Measurement Lab Test Machines Of Touch Current And Protective Conductor Current
                                                                                    
                        
                        
                        
                                                            Measurement Lab Test Machines Of Touch Current And Protective Conductor Current
                                                    
                        
                     IEC 62262 IK Pendulum Hammer , Pendulum Impact Hammer For Specifying Enclosure
                                                                                    
                        
                        
                        
                                                            IEC 62262 IK Pendulum Hammer , Pendulum Impact Hammer For Specifying Enclosure
                                                    
                        
                     Electrodynamic Vibration Test Systems Large Displacement Vertical Or Horizontal
                                                                                    
                        
                        
                        
                                                            Electrodynamic Vibration Test Systems Large Displacement Vertical Or Horizontal
                                                    
                        
                     IEC60598-1 Clause 4.4.4 Fluorescent Lamp Holder Axial Force Tester / Lighting
                                                                                    
                        
                        
                        
                                                            IEC60598-1 Clause 4.4.4 Fluorescent Lamp Holder Axial Force Tester / Lighting